High or low output power selection for condition diagnosis
Rechargeable battery or line power supply, continuous operation, even with dead battery
10 A for 60 seconds, less time waiting to cool, great for charging inductance
High input protection to 600 V, inadvertent connection to line or UPS voltage will not blow a fuse
Heavy duty case: IP 65 lid closed, IP54 operational (battery operation only)
Rotary switch selects one of five test modes, including auto start on connection, giving ease of use
Additional Features and Benefits
Rugged case well suited to transportation with shoulder strap and lead set pouch
Removable lid facilitates easy test lead connection
Operational ingress protection is IP 54 (battery power only) ensuring protection from the elements
7Ah lead acid battery provides extended operation and can be charged whilst operating from line power
Rotary mode switch with bidirectional (current reversal with averaging cancels thermal EMFs), unidirectional, automatic, continuous and inductive modes
Large, clear LCD display with backlight and contrast adjustment
Auto power off function conserves battery
Manufacturer Specs
Electrical Specifications
Resistance/Current Ranges
The green resistance ranges on the keypad indicate low output power (<0.25 W) outputs. Red ranges indicate higher 2.5 W (1 A) and 25 W (10 A) power outputs.
Resolution and Accuracy
Test current accuracy ±10% Voltmeter input impedance >200 kΩ